Hydra-Cell Seal-less Pumps. Positive Displacement Pumps with a seal-less pumping chamber so there are no seals, packing or cups to leak or replace. The seal-less design and check valves enable Hydra-Cell to handle abrasives and particulates that would damage other types of pumps. In addition, Hydra-Cell Seal-less Pumps can run dry indefinitely without damage to the pump.
The multiple-diaphragm design of Hydra-Cell provides virtually pulse-less, linear flow without the need for expensive pulsation dampeners.
D10 Pump Series – Learn More | D35 Pump Series – Learn More | H25 Pump Series – Learn More |
Max Flow: 8.8 gpm Metallic Pump Heads Non-Metallic Pump Heads |
Max Flow: 36.5 gpm Metallic Pump Heads |
Max Flow: 20 gpm Metallic Pump Heads Non-Metallic Pump Heads |
M03 Pump Series – Learn More | ||
Max Flow: 3.1 gpm Metallic Pump Heads Non-Metallic Pump Heads |
The graph above displays the maximum flow capacity at a given pressure for each model series. The table below lists the maximum flow capacity and maximum pressure capability of each model series.
Please Note: Some models do not achieve maximum flow at maximum pressure. Refer to the individual model specifications in this section for precise flow and pressure capabilities by specific pump configuration.
Model | Maximum Capacity gpm (l/min) |
Maximum Discharge Pressure psi (bar) |
Maximum Operating Temperature ºF (ºC)** |
Maximum Inlet Pressure psi (bar) |
||
---|---|---|---|---|---|---|
Non-Metallic* | Metallic | Non-Metallic | Metallic | |||
M03 | 3.1 (11.7) | 350 (24) | 1200 (83) | 140º (60º) | 250º (121º) | 250 (17) |
D10 | 8.8 (33.4) | 350 (24) | 1500 (103) | 140º (60º) | 250º (121º) | 250 (17) |
H25 | 20.0 (75.9) | 350 (24) | 1000 (69) | 140º (60º) | 250º (121º) | 250 (17) |
D35 | 36.5 (138) | N/A | 1500 (103) | N/A | 250º (121º) | 500 (34) |
** Consult factory for correct component selection for temperatures from 160 ̊F (71 ̊C) to 250 ̊F (121 ̊C).
T100 Pump Series – Low Pressure | T100 Pump Series – Medium Pressure | T100 Pump Series – High Pressure |
Max Flow: 96 gpm
Metallic Pump Heads |
Max Flow: 45 gpm
Metallic Pump Heads |
Max Flow: 26 gpm
Metallic Pump Heads |
The graph above displays the maximum flow capacity at a given pressure for each model series. The table below lists the maximum flow capacity and maximum pressure capability of each model series.
Please Note: Some models do not achieve maximum flow at maximum pressure. Refer to the individual model specifications in this section for precise flow and pressure capabilities by specific pump configuration.
Maximum Capacity gpm (l/min) |
Maximum Discharge Pressure psi (bar) |
Maximum Inlet Pressure psi (bar) |
Maximum Operating Temperature * F (C) |
|
---|---|---|---|---|
T100E | 96.0 (366.1) | 1500 (103) | 500 (34) | 180 ̊ (82 ̊ ) |
T100F | 76.5 (289.6) | 1850 (128) | 500 (34) | 180 ̊ (82 ̊ ) |
T100H | 68.0 (257.8) | 2100 (145) | 500 (34) | 180 ̊ (82 ̊ ) |
T100K | 45.0 (170.4) | 3000 (207) | 500 (34) | 180 ̊ (82 ̊ ) |
T100M | 38.0 (143.8) | 3500 (241) | 500 (34) | 180 ̊ (82 ̊ ) |
T100S | 26.0 (98.4) | 5000 (345) | 500 (34) | 180 ̊ (82 ̊ ) |
* Consult factory for correct component selection for temperatures above 180 ̊ F (82 ̊ C) or below 40 ̊ F (4 ̊ C)
Q155 Pump Series Low Pressure |
Q155 Pump Series Medium Pressure |
Max Flow: 195 gpm |
Max Flow: 78 gpm Max Pressure: 3500 psi (241 bar) |
The graph above displays the maximum flow capacity at a given pressure for each model series. The table below lists the maximum flow capacity and maximum pressure capability of each model series.
Please Note: Some models do not achieve maximum flow at maximum pressure. Refer to the individual model specifications in this section for precise flow and pressure capabilities by specific pump configuration.
Maximum Capacity gpm (l/min) |
Maximum Discharge Pressure psi (bar) |
Maximum Inlet Pressure psi (bar) |
Maximum Operating Temperature * F (C) |
|
---|---|---|---|---|
Q155E | 157 (595) | 1500 (103) | 500 (34) | 180 ̊ (82 ̊ ) |
Q155F | 127 (490) | 1850 (127) | 500 (34) | 180 ̊ (82 ̊ ) |
Q155H | 111 (421) | 2100 (144) | 500 (34) | 180 ̊ (82 ̊ ) |
Q155K | 78 (295) | 3000 (207) | 500 (34) | 180 ̊ (82 ̊ ) |
Q155M | 67 (252) | 3500 (241) | 500 (34) | 180 ̊ (82 ̊ ) |
Capable
- Hydra-Cell Seal-less pumps can deal with abrasive liquids
- Tolerates abrasive solids and particulate matter up to 800 microns (depending on pump model) and 9 hardness (Mohs) without the need for fine filtration.
- Multiple diaphragms provide virtually pulse-less flow that exceeds API 675 standards for accuracy, linearity, and repeatability.
- Low-shear pumping action ensures integrity of long-chain structures.
Environmental
- Hydra-Cell Seal-less pumps are environmentally friendly
- Liquids are 100% sealed from the atmosphere.
- No leak path for toxic vapors or harmful gasses.
- No seals to leak any Volatile Organic Compounds (VOC).
- Lower energy costs to operate pump.
Versatile
- Versatility of Hydra-Cell Seal-less pumps is unmatched
- Variety of styles and models to pump a wide range of flow capacities and pressure ratings.
- Hydraulically-balanced diaphragms can pump low-to-high- viscosity liquids throughout the entire pressure range of the pump.
- Available in a variety of construction materials to meet a wide range of applications and ensure optimum pumping life even when handling aggressive fluids.
- Can be fitted with SAE, ANSI or DIN flanges as well as IEC or NEMA motor mounts.
- Can be provided with ATEX certification or other certification to adapt to specific applications or meet international standards.
- Design allows for easy interchangeability of pump head materials and can accommodate mixing different materials with one pump head.
Reliable
- Hydra-Cell Seal-less pumps are most reliable
- Can run dry without damage to the pump.
- Robust design tolerates non-ideal operating conditions.
- No seals, packing or cups to leak or replace.
- Typically runs up to 6,000 hours between lubricating oil changes.
- Can pump acids, slurries and liquids containing up to 40% of non-dissolved solids.
- Does not rely on the fluid being pumped for lubrication.
- No tight tolerances susceptible to corrosion or solid particles.